Fanuc alarm: PS198 - STROKE THAN MINIMUM ANGLE
Values other than multiple integral of the least angle for indexing the index table are commanded.
None currently
- Read more about Fanuc alarm: PS198 - STROKE THAN MINIMUM ANGLE
- Log in to post comments
Values other than multiple integral of the least angle for indexing the index table are commanded.
None currently
The indexing axis of the index table and other control axes are commanded at the same time.
None currently
Selection of drilling axis was not correctly specified in canned cycle for drilling.
None currently
A P value specified in G96 block or parameter 5640 value is in error.
None currently
The axis specified by G28 (automatic reference point return) does not return to the correct reference point at the end of positioning.
None currently
In variable lead thread cutting, the lead increase/decrease amount given by address K is exceeding the maximum command value; or the lead is commanded with minus value or the value exceeding the maximum lead.
None currently
An arc, where the difference of radius values at start point and end point is larger than the parameter set value, was specified. (Parameter 2410)
None currently
Parameter of max. cutting feedrate was set to 0.
None currently
Parameter set value was 0 at maximum feedrate or dr run rate.
None currently
Cutting feederate command (F code) was 0.
None currently