16/18/21

Fanuc alarm: 5115 - SPL : ERROR (M i )

CNC Machine Control Manufacturer
Fanuc
Control Model
16/18/21, 16i/18i/21i, 160i/180i/210i, ,
5115 - SPL : ERROR (M i )

Alarm Description

There is an error in the specification of the rank. No knot is specified. The knot specification has an error. The number of axes exceeds the limits. Other program errors

Additional Suggestions & Alarm Clarification

None currently

Help Others
Post troubleshooting recommendations for (Fanuc alarm: 5115 - SPL : ERROR (M i )) error message below.

Fanuc alarm: 5114 - NOT STOP POSITION (G05.1 Q1)

CNC Machine Control Manufacturer
Fanuc
Control Model
16/18/21, 16i/18i/21i, 160i/180i/210i, , 0i
5114 - NOT STOP POSITION (G05.1 Q1)

Alarm Description

At the time of restart after manual intervention, the coordinates at which the manual intervention occurred have not been restored.

Additional Suggestions & Alarm Clarification

None currently

Help Others
Post troubleshooting recommendations for (Fanuc alarm: 5114 - NOT STOP POSITION (G05.1 Q1)) error message below.

Fanuc alarm: 5113 - CAN NOT ERROR IN MDI MODE (G05.1)

CNC Machine Control Manufacturer
Fanuc
Control Model
16/18/21, 16i/18i/21i, 160i/180i/210i, , 0i
5113 - CAN NOT ERROR IN MDI MODE (G05.1)

Alarm Description

Simple high-precision contour control (G05.1) was specified in MDI mode.

Additional Suggestions & Alarm Clarification

None currently

Help Others
Post troubleshooting recommendations for (Fanuc alarm: 5113 - CAN NOT ERROR IN MDI MODE (G05.1)) error message below.

Fanuc alarm: 5112 - G08 CAN NOT BE COMMANDED (G05.1 G1)

CNC Machine Control Manufacturer
Fanuc
Control Model
16/18/21, 16i/18i/21i, 160i/180i/210i, , 0i
5112 - G08 CAN NOT BE COMMANDED (G05.1 G1)

Alarm Description

Look-ahead control (G08) was specified in simple high-precision contour control mode.

Additional Suggestions & Alarm Clarification

None currently

Help Others
Post troubleshooting recommendations for (Fanuc alarm: 5112 - G08 CAN NOT BE COMMANDED (G05.1 G1)) error message below.

Fanuc alarm: 5111 - IMPROPER MODAL G-CODE (G05.1 G1)

CNC Machine Control Manufacturer
Fanuc
Control Model
16/18/21, 16i/18i/21i, 160i/180i/210i, , 0i
5111 - IMPROPER MODAL G-CODE (G05.1 G1)

Alarm Description

An illegal G code is left modal when simple high-precision contour control mode was specified.

Additional Suggestions & Alarm Clarification

None currently

Help Others
Post troubleshooting recommendations for (Fanuc alarm: 5111 - IMPROPER MODAL G-CODE (G05.1 G1)) error message below.

Fanuc alarm: 5110 - IMPROPER G-CODE (G05.1G1MODE)

CNC Machine Control Manufacturer
Fanuc
Control Model
16/18/21, 16i/18i/21i, 160i/180i/210i, , 0i
5110 - IMPROPER G-CODE (G05.1G1MODE)

Alarm Description

An illegal G code was specified in simple high-precision contour control mode. A command was specified for the index table indexing axis in simple high precision contour control mode.

Additional Suggestions & Alarm Clarification

None currently

Help Others
Post troubleshooting recommendations for (Fanuc alarm: 5110 - IMPROPER G-CODE (G05.1G1MODE) ) error message below.

Fanuc alarm: 5096 - MISMATCH WAITING M-CODE

CNC Machine Control Manufacturer
Fanuc
Control Model
16/18/21, 16i/18i/21i, 160i/180i/210i, ,
5096 - MISMATCH WAITING M-CODE

Alarm Description

Different wait codes (M codes) were specified in HEAD1 and HEAD2.
Correct the program.

Additional Suggestions & Alarm Clarification

None currently

Help Others
Post troubleshooting recommendations for (Fanuc alarm: 5096 - MISMATCH WAITING M-CODE) error message below.

Fanuc alarm: 5085 - SMOOTH IPL ERROR 1

CNC Machine Control Manufacturer
Fanuc
Control Model
16/18/21, 16i/18i/21i, 160i/180i/210i, ,
5085 - SMOOTH IPL ERROR 1

Alarm Description

The command format of a smooth interpolation command block has an error. A block for specifying smooth interpolation contains a syntax error.

Additional Suggestions & Alarm Clarification

None currently

Help Others
Post troubleshooting recommendations for (Fanuc alarm: 5085 - SMOOTH IPL ERROR 1) error message below.

Fanuc alarm: 5082 - DATA SERVER ERROR

CNC Machine Control Manufacturer
Fanuc
Control Model
16/18/21, 16i/18i/21i, 160i/180i/210i, ,
5082 - DATA SERVER ERROR

Alarm Description

This alarm is detailed on the data server message screen.

Additional Suggestions & Alarm Clarification

None currently

Help Others
Post troubleshooting recommendations for (Fanuc alarm: 5082 - DATA SERVER ERROR) error message below.

Fanuc alarm: 5074 - ADDRESS DUPLICATION ERROR

CNC Machine Control Manufacturer
Fanuc
Control Model
16/18/21, 16i/18i/21i, 160i/180i/210i, , 0i
5074 - ADDRESS DUPLICATION ERROR

Alarm Description

The same address has been specified two or more times in a single block. Alternatively, two or more G codes in the same group have been specified in a single block.

Additional Suggestions & Alarm Clarification

None currently

Help Others
Post troubleshooting recommendations for (Fanuc alarm: 5074 - ADDRESS DUPLICATION ERROR) error message below.

Theme by Danetsoft and Danang Probo Sayekti inspired by Maksimer