16/18/21

Fanuc alarm: 5136 - FSSB : NUMBER OF AMPS IS SMALL

CNC Machine Control Manufacturer
Fanuc
Control Model
16/18/21, 16i/18i/21i, 160i/180i/210i, ,
5136 - FSSB : NUMBER OF AMPS IS SMALL

Alarm Description

In comparison with the number of controlled axes, the number of amplifiers
recognized by FSSB is not enough.

Additional Suggestions & Alarm Clarification

None currently

Help Others
Post troubleshooting recommendations for (Fanuc alarm: 5136 - FSSB : NUMBER OF AMPS IS SMALL) error message below.

Fanuc alarm: 5134 - FSSB : OPEN READY TIME OUT

CNC Machine Control Manufacturer
Fanuc
Control Model
16/18/21, 16i/18i/21i, 160i/180i/210i, ,
5134 - FSSB : OPEN READY TIME OUT

Alarm Description

Initialization did not place FSSB in the open ready state.

Additional Suggestions & Alarm Clarification

None currently

Help Others
Post troubleshooting recommendations for (Fanuc alarm: 5134 - FSSB : OPEN READY TIME OUT) error message below.

Fanuc alarm: 5124 - CAN NOT COMMAND SPIRAL(M series)

CNC Machine Control Manufacturer
Fanuc
Control Model
16/18/21, 16i/18i/21i, 160i/180i/210i, ,
5124 - CAN NOT COMMAND SPIRAL(M series)

Alarm Description

A spiral interpolation or conical interpolation was specified in any of the
following modes:
1) Scaling
2) Programmable mirror image
3) Polar coordinate interpolation
In cutter compensation C mode, the center is set as the start point or
end point.

Additional Suggestions & Alarm Clarification

None currently

Help Others
Post troubleshooting recommendations for (Fanuc alarm: 5124 - CAN NOT COMMAND SPIRAL(M series)) error message below.

Fanuc alarm: 5123 - OVER TOLERANCE OF END POINT

CNC Machine Control Manufacturer
Fanuc
Control Model
16/18/21, 16i/18i/21i, 160i/180i/210i, ,
5123 - OVER TOLERANCE OF END POINT

Alarm Description

The difference between a specified end point and the calculated end point exceeds the allowable range (parameter 3471).

Additional Suggestions & Alarm Clarification

None currently

Help Others
Post troubleshooting recommendations for (Fanuc alarm: 5123 - OVER TOLERANCE OF END POINT) error message below.

Fanuc alarm: 5122 - ILLEGAL COMMAND IN SPIRAL (M series)

CNC Machine Control Manufacturer
Fanuc
Control Model
16/18/21, 16i/18i/21i, 160i/180i/210i, ,
5122 - ILLEGAL COMMAND IN SPIRAL (M series)

Alarm Description

A spiral interpolation or conical interpolation command has an error. Specifically, this error is caused by one of the following: 1) L = 0 is specified. 2) Q = 0 is specified. 3) R/, R/, C is specified. 4) Zero is specified as height increment. 5) Three or more axes are specified as the height axes. 6) A height increment is specified when there are two height axes. 7) Conical interpolation is specified when the helical interpolation function is not selected. 8) Q < 0 is specified when radius difference > 0. 9) Q > 0 is specified when radius difference < 0. 10) A height increment is specified when no height axis is specified.

Additional Suggestions & Alarm Clarification

None currently

Help Others
Post troubleshooting recommendations for (Fanuc alarm: 5122 - ILLEGAL COMMAND IN SPIRAL (M series)) error message below.

Fanuc alarm: 5118 - SPL : ERROR

CNC Machine Control Manufacturer
Fanuc
Control Model
16/18/21, 16i/18i/21i, 160i/180i/210i, ,
5118 - SPL : ERROR

Alarm Description

After manual intervention with manual absolute mode set to on, NURBS interpolation was restarted.

Additional Suggestions & Alarm Clarification

None currently

Help Others
Post troubleshooting recommendations for (Fanuc alarm: 5118 - SPL : ERROR) error message below.

Fanuc alarm: 5117 - SPL : ERROR

CNC Machine Control Manufacturer
Fanuc
Control Model
16/18/21, 16i/18i/21i, 160i/180i/210i, ,
5117 - SPL : ERROR

Alarm Description

The first control point of NURBS is incorrect.

Additional Suggestions & Alarm Clarification

None currently

Help Others
Post troubleshooting recommendations for (Fanuc alarm: 5117 - SPL : ERROR) error message below.

Fanuc alarm: 5116 - SPL : ERROR (M i )

CNC Machine Control Manufacturer
Fanuc
Control Model
16/18/21, 16i/18i/21i, 160i/180i/210i, ,
5116 - SPL : ERROR (M i )

Alarm Description

There is a program error in a block under look-ahead control. Monotone increasing of knots is not observed. In NURBS interpolation mode, a mode that cannot be used together is specified.

Additional Suggestions & Alarm Clarification

None currently

Help Others
Post troubleshooting recommendations for (Fanuc alarm: 5116 - SPL : ERROR (M i )) error message below.