16/18/21

Fanuc alarm: 5013 - HPCC: CRC OFS REMAIN AT CANCEL

CNC Machine Control Manufacturer
Fanuc
Control Model
16/18/21, 16i/18i/21i, 160i/180i/210i, ,
5013 - HPCC: CRC OFS REMAIN AT CANCEL

Alarm Description

G05P0 has been specified in G41/G42 mode or with offset remaining.

Additional Suggestions & Alarm Clarification

None currently

Help Others
Post troubleshooting recommendations for (Fanuc alarm: 5013 - HPCC: CRC OFS REMAIN AT CANCEL ) error message below.

Fanuc alarm: 5012 - G05 P10000 ILLEGAL START UP (HPCC)

CNC Machine Control Manufacturer
Fanuc
Control Model
16/18/21, 16i/18i/21i, 160i/180i/210i, ,
5012 - G05 P10000 ILLEGAL START UP (HPCC)

Alarm Description

Function category: High-precision contour control Alarm details: G05 P10000 has been specified in a mode from which the system cannot enter HPCC mode.

Additional Suggestions & Alarm Clarification

None currently

Help Others
Post troubleshooting recommendations for (Fanuc alarm: 5012 - G05 P10000 ILLEGAL START UP (HPCC)) error message below.

Fanuc alarm: 5011 - PARAMETER ZERO (CUT MAX)

CNC Machine Control Manufacturer
Fanuc
Control Model
16/18/21, 16i/18i/21i, 160i/180i/210i, ,
5011 - PARAMETER ZERO (CUT MAX)

Alarm Description

The maximum cutting feedrate (parameter No. 1422, No. 1430, No. 1431, No. 1432) is 0 in the HPCC mode.

Additional Suggestions & Alarm Clarification

None currently

Help Others
Post troubleshooting recommendations for (Fanuc alarm: 5011 - PARAMETER ZERO (CUT MAX) ) error message below.

Fanuc alarm: 5010 - END OF RECORD

CNC Machine Control Manufacturer
Fanuc
Control Model
16/18/21, 16i/18i/21i, 160i/180i/210i, , 0i
5010 - END OF RECORD

Alarm Description

The end of record (%) was specified. I/O is incorrect. modify the program.

Additional Suggestions & Alarm Clarification

None currently

Help Others
Post troubleshooting recommendations for (Fanuc alarm: 5010 - END OF RECORD) error message below.

Fanuc alarm: 5009 - PARAMETER ZERO (DRY RUN)

CNC Machine Control Manufacturer
Fanuc
Control Model
16/18/21, 16i/18i/21i, 160i/180i/210i, ,
5009 - PARAMETER ZERO (DRY RUN)

Alarm Description

The maximum feedrate (parameter No. 1422) or the feedrate in dry run (parameter No. 1410) is 0 in the HPCC model.

Additional Suggestions & Alarm Clarification

None currently

Help Others
Post troubleshooting recommendations for (Fanuc alarm: 5009 - PARAMETER ZERO (DRY RUN)) error message below.

Fanuc alarm: 5006 - TOOMANYWORDINONE BLOCK

CNC Machine Control Manufacturer
Fanuc
Control Model
16/18/21, 16i/18i/21i, 160i/180i/210i, ,
5006 - TOOMANYWORDINONE BLOCK

Alarm Description

The number of words specified in a block exceeded 26 in the HPCC mode.

Additional Suggestions & Alarm Clarification

None currently

Help Others
Post troubleshooting recommendations for (Fanuc alarm: 5006 - TOOMANYWORDINONE BLOCK) error message below.

Fanuc alarm: 5004 - HPCC NOT READY

CNC Machine Control Manufacturer
Fanuc
Control Model
16/18/21, 16i/18i/21i, 160i/180i/210i, ,
5004 - HPCC NOT READY

Alarm Description

High-precision contour control is not ready.

Additional Suggestions & Alarm Clarification

None currently

Help Others
Post troubleshooting recommendations for (Fanuc alarm: 5004 - HPCC NOT READY) error message below.

Fanuc alarm: 5003 - ILLEGAL PARAMETER (HPCC) (M series)

CNC Machine Control Manufacturer
Fanuc
Control Model
16/18/21, 16i/18i/21i, 160i/180i/210i, ,
5003 - ILLEGAL PARAMETER (HPCC) (M series)

Alarm Description

There is an invalid parameter.

Additional Suggestions & Alarm Clarification

None currently

Help Others
Post troubleshooting recommendations for (Fanuc alarm: 5003 - ILLEGAL PARAMETER (HPCC) (M series)) error message below.

Fanuc alarm: 5000 - ILLEGAL COMMAND CODE (M series)

CNC Machine Control Manufacturer
Fanuc
Control Model
16/18/21, 16i/18i/21i, 160i/180i/210i, ,
5000 - ILLEGAL COMMAND CODE (M series)

Alarm Description

The specified code was incorrect in the high-precision contour control (HPCC) mode.

Additional Suggestions & Alarm Clarification

None currently

Help Others
Post troubleshooting recommendations for (Fanuc alarm: 5000 - ILLEGAL COMMAND CODE (M series)) error message below.

Theme by Danetsoft and Danang Probo Sayekti inspired by Maksimer