Fanuc

Fanuc alarm: 80 - G37ARRIVALSIGNALNOT ASSERTED

CNC Machine Control Manufacturer
Fanuc
Control Model
16/18/21, 16i/18i/21i, 160i/180i/210i, 0/00/0-mate, 0i
80 - G37ARRIVALSIGNALNOT ASSERTED

Alarm Description

In the automatic tool length measurement function (G37), the measurement position reach signal (XAE, YAE, or ZAE) is not turned on within an area specified in parameter 6254 6255. In the automatic tool compensation function (G36, G37), the measurement position reach signal (XAE or ZAE) is not turned on within an area specified in parameter 6254 . This is due to a setting or operator error.

Additional Suggestions & Alarm Clarification

None currently

Help Others
Post troubleshooting recommendations for (Fanuc alarm: 80 - G37ARRIVALSIGNALNOT ASSERTED) error message below.

Fanuc alarm: 79 - PROGRAM VERIFY ERROR

CNC Machine Control Manufacturer
Fanuc
Control Model
16/18/21, 16i/18i/21i, 160i/180i/210i, 0/00/0-mate, 0i
79 - PROGRAM VERIFY ERROR

Alarm Description

In memory or program collation, a program in memory does not agree with that read from an external I/O device. Check both the programs in memory and those from the external device.

Additional Suggestions & Alarm Clarification

None currently

Help Others
Post troubleshooting recommendations for (Fanuc alarm: 79 - PROGRAM VERIFY ERROR) error message below.

Fanuc alarm: 78 - NUMBER NOT FOUND

CNC Machine Control Manufacturer
Fanuc
Control Model
16/18/21, 16i/18i/21i, 160i/180i/210i, 0/00/0-mate, 0i
78 - NUMBER NOT FOUND

Alarm Description

A program number or a sequence number which was specified by address P in the block which includes an M98, M99, M65 or G66 was not found. The sequence number specified by a GOTO statement was not found. Otherwise, a called program is being edited in background processing. Correct the program, or discontinue the background editing.

Additional Suggestions & Alarm Clarification

None currently

Help Others
Post troubleshooting recommendations for (Fanuc alarm: 78 - NUMBER NOT FOUND) error message below.

Fanuc alarm: 77 - SUB PROGRAM NESTING ERROR

CNC Machine Control Manufacturer
Fanuc
Control Model
16/18/21, 16i/18i/21i, 160i/180i/210i, 0/00/0-mate, 0i
77 - SUB PROGRAM NESTING ERROR

Alarm Description

The subprogram was called in five folds. Modify the program.

Additional Suggestions & Alarm Clarification

None currently

Help Others
Post troubleshooting recommendations for (Fanuc alarm: 77 - SUB PROGRAM NESTING ERROR) error message below.

Fanuc alarm: 76 - ADDRESS P NOT DEFINED

CNC Machine Control Manufacturer
Fanuc
Control Model
16/18/21, 16i/18i/21i, 160i/180i/210i, 0/00/0-mate, 0i
76 - ADDRESS P NOT DEFINED

Alarm Description

Address P (program number) was not commanded in the block which includes an M98, G65, or G66 command. Modify the program.

Additional Suggestions & Alarm Clarification

None currently

Help Others
Post troubleshooting recommendations for (Fanuc alarm: 76 - ADDRESS P NOT DEFINED) error message below.

Fanuc alarm: 75 - PROTECT

CNC Machine Control Manufacturer
Fanuc
Control Model
16/18/21, 16i/18i/21i, 160i/180i/210i, 0/00/0-mate, 0i
75 - PROTECT

Alarm Description

An attempt was made to register a program whose number was protected.

Additional Suggestions & Alarm Clarification

None currently

Help Others
Post troubleshooting recommendations for (Fanuc alarm: 75 - PROTECT) error message below.

Fanuc alarm: 74 - ILLEGAL PROGRAM NUMBER

CNC Machine Control Manufacturer
Fanuc
Control Model
16/18/21, 16i/18i/21i, 160i/180i/210i, 0/00/0-mate, 0i
74 - ILLEGAL PROGRAM NUMBER

Alarm Description

The program number is other than 1 to 9999. Modify the program number.

Additional Suggestions & Alarm Clarification

None currently

Help Others
Post troubleshooting recommendations for (Fanuc alarm: 74 - ILLEGAL PROGRAM NUMBER) error message below.

Fanuc alarm: 73 - PROGRAM NUMBER ALREADY IN USE

CNC Machine Control Manufacturer
Fanuc
Control Model
16/18/21, 16i/18i/21i, 160i/180i/210i, 0/00/0-mate, 0i
73 - PROGRAM NUMBER ALREADY IN USE

Alarm Description

The commanded program number has already been used. Change the program number or delete unnecessary programs and execute program registration again.

Additional Suggestions & Alarm Clarification

None currently

Help Others
Post troubleshooting recommendations for (Fanuc alarm: 73 - PROGRAM NUMBER ALREADY IN USE) error message below.

Fanuc alarm: 72 - TOO MANY PROGRAMS

CNC Machine Control Manufacturer
Fanuc
Control Model
16/18/21, 16i/18i/21i, 160i/180i/210i, 0/00/0-mate, 0i
72 - TOO MANY PROGRAMS

Alarm Description

The number of programs to be stored exceeded 63 (basic), 125 (option), 200 (option), 400 (option) or 1000 (option). Delete unnecessary programs and execute program registration again.

Additional Suggestions & Alarm Clarification

None currently

Help Others
Post troubleshooting recommendations for (Fanuc alarm: 72 - TOO MANY PROGRAMS) error message below.

Fanuc alarm: 71 - DATA NOT FOUND

CNC Machine Control Manufacturer
Fanuc
Control Model
16/18/21, 16i/18i/21i, 160i/180i/210i, 0/00/0-mate, 0i
71 - DATA NOT FOUND

Alarm Description

The address to be searched was not found. Or the program with specified program number was not found in program number search. Check the data.

Additional Suggestions & Alarm Clarification

None currently

Help Others
Post troubleshooting recommendations for (Fanuc alarm: 71 - DATA NOT FOUND) error message below.