Fanuc

Fanuc alarm: 4144 - DATA SENDING ERROR

CNC Machine Control Manufacturer
Fanuc
Control Model
16/18/21, 16i/18i/21i, 160i/180i/210i, ,
4144 - DATA SENDING ERROR

Alarm Description

The READY and SEND signals are out of sync with each other between the CNC and laser controller, so that data cannot be sent.

Additional Suggestions & Alarm Clarification

None currently

Help Others
Post troubleshooting recommendations for (Fanuc alarm: 4144 - DATA SENDING ERROR ) error message below.

Fanuc alarm: 4143 - OVER CURRENT ERROR

CNC Machine Control Manufacturer
Fanuc
Control Model
16/18/21, 16i/18i/21i, 160i/180i/210i, ,
4143 - OVER CURRENT ERROR

Alarm Description

With the YAG laser, the current data sent to the oscillator has exceeded the allowable level.

Additional Suggestions & Alarm Clarification

None currently

Help Others
Post troubleshooting recommendations for (Fanuc alarm: 4143 - OVER CURRENT ERROR ) error message below.

Fanuc alarm: 4142 - DATA RECEIVING ERROR

CNC Machine Control Manufacturer
Fanuc
Control Model
16/18/21, 16i/18i/21i, 160i/180i/210i, ,
4142 - DATA RECEIVING ERROR

Alarm Description

A data resend request from the laser controller is kept for more than 10 seconds.

Additional Suggestions & Alarm Clarification

None currently

Help Others
Post troubleshooting recommendations for (Fanuc alarm: 4142 - DATA RECEIVING ERROR ) error message below.

Fanuc alarm: 4141 - INITIAL LOADING

CNC Machine Control Manufacturer
Fanuc
Control Model
16/18/21, 16i/18i/21i, 160i/180i/210i, ,
4141 - INITIAL LOADING

Alarm Description

With the YAG laser, an error has occurred during initial loading of laser machining data into the oscillator.

Additional Suggestions & Alarm Clarification

None currently

Help Others
Post troubleshooting recommendations for (Fanuc alarm: 4141 - INITIAL LOADING ) error message below.

Fanuc alarm: 4139 - MIXER PRESSURE SWITCH ERROR

CNC Machine Control Manufacturer
Fanuc
Control Model
16/18/21, 16i/18i/21i, 160i/180i/210i, ,
4139 - MIXER PRESSURE SWITCH ERROR

Alarm Description

This alarm is issued if the laser gas supply pressure has decreased, while the tank supply pressure has not.

Additional Suggestions & Alarm Clarification

None currently

Help Others
Post troubleshooting recommendations for (Fanuc alarm: 4139 - MIXER PRESSURE SWITCH ERROR) error message below.

Fanuc alarm: 4138 - INSUFFICIENT DEGREE OF VACUUM

CNC Machine Control Manufacturer
Fanuc
Control Model
16/18/21, 16i/18i/21i, 160i/180i/210i, ,
4138 - INSUFFICIENT DEGREE OF VACUUM

Alarm Description

This alarm is issued if the specified degree of vacuum has not been reached within the predetermined time during evacuation of the mixer.

Additional Suggestions & Alarm Clarification

None currently

Help Others
Post troubleshooting recommendations for (Fanuc alarm: 4138 - INSUFFICIENT DEGREE OF VACUUM) error message below.

Fanuc alarm: 4137 - MIXER POWER FAILURE

CNC Machine Control Manufacturer
Fanuc
Control Model
16/18/21, 16i/18i/21i, 160i/180i/210i, ,
4137 - MIXER POWER FAILURE

Alarm Description

This alarm is issued if the power to the relay PCB in the mixer is under an abnormal condition.

Additional Suggestions & Alarm Clarification

None currently

Help Others
Post troubleshooting recommendations for (Fanuc alarm: 4137 - MIXER POWER FAILURE ) error message below.

Fanuc alarm: 4136 - INTERNAL PRESSURE TOO HIGH

CNC Machine Control Manufacturer
Fanuc
Control Model
16/18/21, 16i/18i/21i, 160i/180i/210i, ,
4136 - INTERNAL PRESSURE TOO HIGH

Alarm Description

This alarm is issued if the pressure in the mixer is too high (1 MPa).

Additional Suggestions & Alarm Clarification

None currently

Help Others
Post troubleshooting recommendations for (Fanuc alarm: 4136 - INTERNAL PRESSURE TOO HIGH ) error message below.

Fanuc alarm: 4132 - PARAMETER WAS CHANGED

CNC Machine Control Manufacturer
Fanuc
Control Model
16/18/21, 16i/18i/21i, 160i/180i/210i, ,
4132 - PARAMETER WAS CHANGED

Alarm Description

Parameters No.15223, No. 15242, and No. 15243 have been changed.

Additional Suggestions & Alarm Clarification

None currently

Help Others
Post troubleshooting recommendations for (Fanuc alarm: 4132 - PARAMETER WAS CHANGED ) error message below.

Theme by Danetsoft and Danang Probo Sayekti inspired by Maksimer