Fanuc

Fanuc alarm: 4506 - ILLEGAL COMMAND IN SHARE PROOFS

CNC Machine Control Manufacturer
Fanuc
Control Model
16/18/21, 16i/18i/21i, 160i/180i/210i, ,
4506 - ILLEGAL COMMAND IN SHARE PROOFS

Alarm Description

In a shear proof (G86) command, the tool size (P) was set to zero, or the blanking length (I) was 1.5 times larger than the tool size (P) or less. Alternatively, I, J, or P was not specified.

Additional Suggestions & Alarm Clarification

None currently

Help Others
Post troubleshooting recommendations for (Fanuc alarm: 4506 - ILLEGAL COMMAND IN SHARE PROOFS) error message below.

Fanuc alarm: 4505 - ILLEGAL COMMAND IN GRID

CNC Machine Control Manufacturer
Fanuc
Control Model
16/18/21, 16i/18i/21i, 160i/180i/210i, ,
4505 - ILLEGAL COMMAND IN GRID

Alarm Description

In a grid (G78, G79) command, the number of holes (P, K) was set to zero or a negative value. Alternatively, I, J, K, or P was not specified.

Additional Suggestions & Alarm Clarification

None currently

Help Others
Post troubleshooting recommendations for (Fanuc alarm: 4505 - ILLEGAL COMMAND IN GRID) error message below.

Fanuc alarm: 4504 - ILLEGAL COMMAND IN ARC

CNC Machine Control Manufacturer
Fanuc
Control Model
16/18/21, 16i/18i/21i, 160i/180i/210i, ,
4504 - ILLEGAL COMMAND IN ARC

Alarm Description

In an arc (G77) command, the radius (I) or the number of holes (K) was set to zero or a negative value. Alternatively, I, J, K, or P was not specified.

Additional Suggestions & Alarm Clarification

None currently

Help Others
Post troubleshooting recommendations for (Fanuc alarm: 4504 - ILLEGAL COMMAND IN ARC) error message below.

Fanuc alarm: 4503 - ILLEGAL COMMAND IN LINE AT ANGLE

CNC Machine Control Manufacturer
Fanuc
Control Model
16/18/21, 16i/18i/21i, 160i/180i/210i, ,
4503 - ILLEGAL COMMAND IN LINE AT ANGLE

Alarm Description

In a line-at-angle (G76) command, the number of holes (K) was set to zero or a negative value. Alternatively, I, J, or K was not specified.

Additional Suggestions & Alarm Clarification

None currently

Help Others
Post troubleshooting recommendations for (Fanuc alarm: 4503 - ILLEGAL COMMAND IN LINE AT ANGLE) error message below.

Fanuc alarm: 4502 - ILLEGAL COMMAND IN BOLT HOLE

CNC Machine Control Manufacturer
Fanuc
Control Model
16/18/21, 16i/18i/21i, 160i/180i/210i, ,
4502 - ILLEGAL COMMAND IN BOLT HOLE

Alarm Description

In a bolt hole circle (G26) command, the radius (I) was set to zero or a negative value, or the number of holes (K) was set to zero. Alternatively, I, J, or K was not specified.

Additional Suggestions & Alarm Clarification

None currently

Help Others
Post troubleshooting recommendations for (Fanuc alarm: 4502 - ILLEGAL COMMAND IN BOLT HOLE) error message below.

Fanuc alarm: 4500 - REPOSITIONING INHIBITED

CNC Machine Control Manufacturer
Fanuc
Control Model
16/18/21, 16i/18i/21i, 160i/180i/210i, ,
4500 - REPOSITIONING INHIBITED

Alarm Description

A repositioning command was specified in the circular interpolation (G02, G03) mode.

Additional Suggestions & Alarm Clarification

None currently

Help Others
Post troubleshooting recommendations for (Fanuc alarm: 4500 - REPOSITIONING INHIBITED) error message below.

Fanuc alarm: 4149 - SHUTTER OPEN

CNC Machine Control Manufacturer
Fanuc
Control Model
16/18/21, 16i/18i/21i, 160i/180i/210i, ,
4149 - SHUTTER OPEN

Alarm Description

The RUN-ON operation is performed while the shutter is open.

Additional Suggestions & Alarm Clarification

None currently

Help Others
Post troubleshooting recommendations for (Fanuc alarm: 4149 - SHUTTER OPEN ) error message below.

Fanuc alarm: 4148 - REG NO. NOT COMMAND

CNC Machine Control Manufacturer
Fanuc
Control Model
16/18/21, 16i/18i/21i, 160i/180i/210i, ,
4148 - REG NO. NOT COMMAND

Alarm Description

With the YAG laser, an output command is specified with no execution register number specified.

Additional Suggestions & Alarm Clarification

None currently

Help Others
Post troubleshooting recommendations for (Fanuc alarm: 4148 - REG NO. NOT COMMAND ) error message below.

Fanuc alarm: 4146 - POWER OVER ERROR

CNC Machine Control Manufacturer
Fanuc
Control Model
16/18/21, 16i/18i/21i, 160i/180i/210i, ,
4146 - POWER OVER ERROR

Alarm Description

With the YAG laser, the power calculated from the data sent to the oscillator has exceeded the allowable level.

Additional Suggestions & Alarm Clarification

None currently

Help Others
Post troubleshooting recommendations for (Fanuc alarm: 4146 - POWER OVER ERROR ) error message below.

Fanuc alarm: 4145 - TOUCH DISPLAY

CNC Machine Control Manufacturer
Fanuc
Control Model
16/18/21, 16i/18i/21i, 160i/180i/210i, ,
4145 - TOUCH DISPLAY

Alarm Description

See the touch display of the oscillator for the YAG laser.

Additional Suggestions & Alarm Clarification

None currently

Help Others