0/00/0-mate

Fanuc alarm: 116 - WRITE PROTECTED VARIABLE

CNC Machine Control Manufacturer
Fanuc
Control Model
16/18/21, 16i/18i/21i, 160i/180i/210i, 0/00/0-mate, 0i
116 - WRITE PROTECTED VARIABLE

Alarm Description

The left side of substitution statement is a variable whose substitution is inhibited. Modify the program.

Additional Suggestions & Alarm Clarification

None currently

Help Others
Post troubleshooting recommendations for (Fanuc alarm: 116 - WRITE PROTECTED VARIABLE) error message below.

Fanuc alarm: 115 - ILLEGAL VARIABLE NUMBER

CNC Machine Control Manufacturer
Fanuc
Control Model
16/18/21, 16i/18i/21i, 160i/180i/210i, 0/00/0-mate, 0i
115 - ILLEGAL VARIABLE NUMBER

Alarm Description

A value not defined as a variable number is designated in the custom macro or in high-speed cycle machining. The header contents are improper. This alarm is given in the following cases: High speed cycle machining 1. The header corresponding to the specified machining cycle number called is not found. 2. The cycle connection data value is out of the allowable range (0 -999). 3. The number of data in the header is out of the allowable range (0 -32767). 4. The start data variable number of executable format data is out of the allowable range (#20000 -#85535). 5. The last storing data variable number of executable format data is out of the allowable range (#85535). 6. The storing start data variable number of executable format data is overlapped with the variable number used in the header. Modify the program.

Additional Suggestions & Alarm Clarification

None currently

Help Others
Post troubleshooting recommendations for (Fanuc alarm: 115 - ILLEGAL VARIABLE NUMBER) error message below.

Fanuc alarm: 114 - FORMAT ERROR IN MACRO

CNC Machine Control Manufacturer
Fanuc
Control Model
16/18/21, 16i/18i/21i, 160i/180i/210i, 0/00/0-mate, 0i
114 - FORMAT ERROR IN MACRO

Alarm Description

There is an error in the formats. Modify the program.

Additional Suggestions & Alarm Clarification

None currently

Help Others
Post troubleshooting recommendations for (Fanuc alarm: 114 - FORMAT ERROR IN MACRO) error message below.

Fanuc alarm: 113 - IMPROPER COMMAND

CNC Machine Control Manufacturer
Fanuc
Control Model
16/18/21, 16i/18i/21i, 160i/180i/210i, 0/00/0-mate, 0i
113 - IMPROPER COMMAND

Alarm Description

A function which cannot be used in custom macro is commanded. Modify the program.

Additional Suggestions & Alarm Clarification

None currently

Help Others
Post troubleshooting recommendations for (Fanuc alarm: 113 - IMPROPER COMMAND) error message below.

Fanuc alarm: 112 - DIVIDED BY ZERO

CNC Machine Control Manufacturer
Fanuc
Control Model
16/18/21, 16i/18i/21i, 160i/180i/210i, 0/00/0-mate, 0i
112 - DIVIDED BY ZERO

Alarm Description

Division by zero was specified. (including tan 90?) Modify the program.

Additional Suggestions & Alarm Clarification

None currently

Help Others
Post troubleshooting recommendations for (Fanuc alarm: 112 - DIVIDED BY ZERO) error message below.

Fanuc alarm: 111 - CALCULATED DATA OVERFLOW

CNC Machine Control Manufacturer
Fanuc
Control Model
16/18/21, 16i/18i/21i, 160i/180i/210i, 0/00/0-mate, 0i
111 - CALCULATED DATA OVERFLOW

Alarm Description

The result of calculation turns out to be invalid, an alarm No.111 is issued. --1047 to -10--29,0,10--29 to 1047 Modify the program.

Additional Suggestions & Alarm Clarification

None currently

Help Others
Post troubleshooting recommendations for (Fanuc alarm: 111 - CALCULATED DATA OVERFLOW) error message below.

Fanuc alarm: 110 - DATA OVERFLOW

CNC Machine Control Manufacturer
Fanuc
Control Model
16/18/21, 16i/18i/21i, 160i/180i/210i, 0/00/0-mate, 0i
110 - DATA OVERFLOW

Alarm Description

The absolute value of fixed decimal point display data exceeds the allowable range. Modify the program.

Additional Suggestions & Alarm Clarification

None currently

Help Others
Post troubleshooting recommendations for (Fanuc alarm: 110 - DATA OVERFLOW) error message below.

Fanuc alarm: 101 - PLEASE CLEAR MEMORY

CNC Machine Control Manufacturer
Fanuc
Control Model
16/18/21, 16i/18i/21i, 160i/180i/210i, 0/00/0-mate, 0i
101 - PLEASE CLEAR MEMORY

Alarm Description

The power turned off while rewriting the memory by program edit operation. If this alarm has occurred, press Reset while pressing Program key, and only the program being edited will be deleted. Register the deleted program.

Additional Suggestions & Alarm Clarification

None currently

Help Others
Post troubleshooting recommendations for (Fanuc alarm: 101 - PLEASE CLEAR MEMORY) error message below.

Fanuc alarm: 100 - PARAMETER WRITE ENABLE

CNC Machine Control Manufacturer
Fanuc
Control Model
16/18/21, 16i/18i/21i, 160i/180i/210i, 0/00/0-mate, 0i
100 - PARAMETER WRITE ENABLE

Alarm Description

On the PARAMETER (SETTING) screen, PWE (parameter writing enabled) is set to 1. Set it to 0, then reset the system.

Additional Suggestions & Alarm Clarification

None currently

Help Others
Post troubleshooting recommendations for (Fanuc alarm: 100 - PARAMETER WRITE ENABLE) error message below.

Fanuc alarm: 99 - MDI EXEC NOT ALLOWED AFT. SEARCH

CNC Machine Control Manufacturer
Fanuc
Control Model
16/18/21, 16i/18i/21i, 160i/180i/210i, 0/00/0-mate, 0i
99 - MDI EXEC NOT ALLOWED AFT. SEARCH

Alarm Description

After completion of search in program restart, a move command is given with MDI. Move axis before a move command or don

Additional Suggestions & Alarm Clarification

None currently

Help Others
Post troubleshooting recommendations for (Fanuc alarm: 99 - MDI EXEC NOT ALLOWED AFT. SEARCH) error message below.

Theme by Danetsoft and Danang Probo Sayekti inspired by Maksimer