Yasnac alarm: 361 - PG ERROR (X)
PG ERROR X
- Read more about Yasnac alarm: 361 - PG ERROR (X)
- Log in to post comments
Yasnac LX3 CNC machine control alarms and error codes for troubleshooting and repair of CNC's.
PG ERROR X
OVERLOAD (2) (CONTRACTOR UNIT) CEILING RESISTANCE, OTHERS.
OVERLOAD (1) Z
Overload condition occurred! Determine if internal in servo drive. May swap drives with same part number but you will loose home position so they must be reset. Megohm motor, check for load in axis by turning screws by hand if axis does not have a brake.
OVERLOAD (1) X
Overload condition occurred! Determine if internal in servo drive. May swap drives with same part number but you will loose home position so they must be reset. Megohm motor, check for load in axis by turning screws by hand if axis does not have a brake.
SERVO ERROR Z
Check Drive LEDS for errors or Plug in Pendant into drive to read errors for Newer controls.
SERVO ERROR X
Check Drive LEDS for errors or Plug in Pendant into drive to read errors for Newer controls.
FUSE BLOWN Z
Check for Fuses and Breakers on Servo Pack drive.
FUSE BLOWN X
Check for Fuses and Breakers on Servo Pack drive.
EMERGENCY STOP
PC CPU IS IN ABNORMAL STATE. (SET "0" IN #6014 D7 TO RESET THE ERROR).