Yasnac-I80 CNC alarm: #0112
(1) M91 FORMAT ERROR (2) P is not specified in the M91 block.
- Read more about Yasnac-I80 CNC alarm: #0112
- Log in to post comments
Yasnac I80 CNC alarms database listing and reference.
(1) M91 FORMAT ERROR (2) P is not specified in the M91 block.
(1) M CODE DIGITS OVER (2) Number of M digit commands is excessive.
(1) MULTIPLE M CODE (2) Command is for mulitple Mcodes althrough there is no one block multiple command option.
(1) "(", ")" ERROR (2) Nest is " ( ". 3) " ) " is used without " ( ". 4) There is no ") - for "( ".
(1) DOUBLE ADDRESS (2) Command is over two times for the same address in one block.
(1) UNUSABLE AXIS (2) Command is for an undefined axis.
(1) NUMERIC DATA OVERFLOW (2) Numeric value input data overflow. (characters being exceeded)
(1) UNUSABLE CHARACTER (2) Command is for characters that cannot be used in the significant information section.
(1) "-", "-" MISUSE (2) Address/data not being used correctly.
(1) ADDRESS/DATA MI SUSE (2) There are no data after the address, or command was for data without address.
Theme by Danetsoft and Danang Probo Sayekti inspired by Maksimer