Fanuc

Fanuc alarm: SV003 - ABNORMAL CURRENT IN SERVO

CNC Machine Control Manufacturer
Fanuc
Control Model
10/11/12
SV003 - ABNORMAL CURRENT IN SERVO
Alarm Description

An overcurrent was detected in the velocity control circuit.

Additional Suggestions & Alarm Clarification

None currently

Help Others
Any additional suggestions or recommendations on the Fanuc alarm: SV003 - ABNORMAL CURRENT IN SERVO message please post comments below.

Fanuc alarm: SV002 - BREAKER (FEED-CTL-UNIT) OFF

CNC Machine Control Manufacturer
Fanuc
Control Model
10/11/12
SV002 - BREAKER (FEED-CTL-UNIT) OFF
Alarm Description

Velocity control circuit breaker was turned off.

Additional Suggestions & Alarm Clarification

None currently

Help Others
Any additional suggestions or recommendations on the Fanuc alarm: SV002 - BREAKER (FEED-CTL-UNIT) OFF message please post comments below.

Fanuc alarm: SV001 - EXCESS CURRENT IN SERVO

CNC Machine Control Manufacturer
Fanuc
Control Model
10/11/12
SV001 - EXCESS CURRENT IN SERVO
Alarm Description

Servo motor was detected to have been overload. (Overload)

Additional Suggestions & Alarm Clarification

None currently

Help Others
Any additional suggestions or recommendations on the Fanuc alarm: SV001 - EXCESS CURRENT IN SERVO message please post comments below.

Fanuc alarm: SV000 - TACOGENERATOR DISCONNECT

CNC Machine Control Manufacturer
Fanuc
Control Model
10/11/12
SV000 - TACOGENERATOR DISCONNECT
Alarm Description

Tachogenerator disconnect alarm was detected.

Additional Suggestions & Alarm Clarification

Some drives have a jumper to jump out this circuit which will allow you to verify operation or even get you up and running for a short time. Recommend talking with Fanuc before you take this step.

Help Others
Any additional suggestions or recommendations on the Fanuc alarm: SV000 - TACOGENERATOR DISCONNECT message please post comments below.

Fanuc alarm: PC510 - MIC TYPE MISS MATCH

CNC Machine Control Manufacturer
Fanuc
Control Model
10/11/12
PC510 - MIC TYPE MISS MATCH
Alarm Description

MIC (Machine Interface Converter) does not match with the setting on the PC side.

Additional Suggestions & Alarm Clarification

None currently

Help Others
Any additional suggestions or recommendations on the Fanuc alarm: PC510 - MIC TYPE MISS MATCH message please post comments below.

Fanuc alarm: PC500 - WATCH DOG ALARM

CNC Machine Control Manufacturer
Fanuc
Control Model
10/11/12
PC500 - WATCH DOG ALARM
Alarm Description

PMC watch dog alarm occurred.

Additional Suggestions & Alarm Clarification

Check all cables and connections to boards in cabinet.

Help Others
Any additional suggestions or recommendations on the Fanuc alarm: PC500 - WATCH DOG ALARM message please post comments below.

Fanuc alarm: PC030 - PC ERROR

CNC Machine Control Manufacturer
Fanuc
Control Model
10/11/12
PC030 - PC ERROR
Alarm Description

I/O unit was not correctly allocated.

Additional Suggestions & Alarm Clarification

None currently

Help Others
Any additional suggestions or recommendations on the Fanuc alarm: PC030 - PC ERROR message please post comments below.

Fanuc alarm: PC020 - PC ERROR

CNC Machine Control Manufacturer
Fanuc
Control Model
10/11/12
PC020 - PC ERROR
Alarm Description

PMC RAM parity error occurred.

Additional Suggestions & Alarm Clarification

None currently

Help Others
Any additional suggestions or recommendations on the Fanuc alarm: PC020 - PC ERROR message please post comments below.

Fanuc alarm: PC010 - PC ERROR

CNC Machine Control Manufacturer
Fanuc
Control Model
10/11/12
PC010 - PC ERROR
Alarm Description

PMC ROM parity error occurred.

Additional Suggestions & Alarm Clarification

None currently

Help Others
Any additional suggestions or recommendations on the Fanuc alarm: PC010 - PC ERROR message please post comments below.