Fanuc alarm: SR841 - CD OFF (3)
Signal quality detection signal of reader/puncher interface 3 turned off.
Check that RS232 cable is connected properly. Try another RS232 cable.
- Read more about Fanuc alarm: SR841 - CD OFF (3)
- Log in to post comments
Signal quality detection signal of reader/puncher interface 3 turned off.
Check that RS232 cable is connected properly. Try another RS232 cable.
Data set ready signal of reader/puncher interface 3 turned off.
Check that RS232 cable is connected properly. Try another RS232 cable.
Data exceeding 10 characters were received after sending the stop code (DC3) when the NC receives data by reader/puncher interface 2.
None currently
Stop bit of a character received by reader/puncher interface 2 was not detected.
Check stop bit setting in RS232 software
The next character was received before reading a character received by reader/puncher interface 2
Check your RS232 Settings
Signal quality detection signal of reader/puncher interface 2 turned off.
Check that RS232 cable is connected properly. Try another RS232 cable.
Data set ready signal of reader/puncher interface 2 turned off.
Check that RS232 cable is connected properly. Try another RS232 cable.
Data exceeding 10 characters were received after sending the stop code (DC3) when the NC receives data by reader/puncher interface 1.
Try turning baudrate for RS232 down and see if problem goes away.
Stop bit of a character received by reader/puncher interface 1 was not detected.
Check stop bit setting in RS232 software
The next character was received before reading a character received by reader/puncher interface 1.
Check your RS232 Settings
Theme by Danetsoft and Danang Probo Sayekti inspired by Maksimer