16/18/21

Fanuc alarm: 94 - P TYPE NOT ALLOWED (COORD CHG)

CNC Machine Control Manufacturer
Fanuc
Control Model
16/18/21, 16i/18i/21i, 160i/180i/210i, 0/00/0-mate, 0i
94 - P TYPE NOT ALLOWED (COORD CHG)

Alarm Description

P type cannot be specified when the program is restarted. (After the automatic operation was interrupted, the coordinate system setting operation was performed.) Perform the correct operation according to the operator

Additional Suggestions & Alarm Clarification

None currently

Help Others
Post troubleshooting recommendations for (Fanuc alarm: 94 - P TYPE NOT ALLOWED (COORD CHG)) error message below.

Fanuc alarm: 92 - AXES NOT ON THE REFERENCE POINT

CNC Machine Control Manufacturer
Fanuc
Control Model
16/18/21, 16i/18i/21i, 160i/180i/210i, 0/00/0-mate, 0i
92 - AXES NOT ON THE REFERENCE POINT

Alarm Description

The commanded axis by G27 (Reference position return check) did not return to the reference position. Automatic reference position return (G28) or the commanded axis by
G27 (Reference position return check) did not return to the reference
position.

Additional Suggestions & Alarm Clarification

None currently

Help Others
Post troubleshooting recommendations for (Fanuc alarm: 92 - AXES NOT ON THE REFERENCE POINT) error message below.

Fanuc alarm: 91 - REFERENCE RETURN INCOMPLETE or MANUAL RETURN TO THE REFERENCEPOSITION IS IMPOSSIBLEBECAUSE OF A TEMPORARYSTOP.

CNC Machine Control Manufacturer
Fanuc
Control Model
16/18/21, 16i/18i/21i, 160i/180i/210i, 0/00/0-mate, 0i
91 - REFERENCE RETURN INCOMPLETE or MANUAL RETURN TO THE REFERENCEPOSITION IS IMPOSSIBLEBECAUSE OF A TEMPORARYSTOP.

Alarm Description

Manual reference position return cannot be performed when automatic operation is halted.

Additional Suggestions & Alarm Clarification

None currently

Help Others
Post troubleshooting recommendations for (Fanuc alarm: 91 - REFERENCE RETURN INCOMPLETE or MANUAL RETURN TO THE REFERENCEPOSITION IS IMPOSSIBLEBECAUSE OF A TEMPORARYSTOP.) error message below.

Fanuc alarm: 90 - REFERENCE RETURN INCOMPLETE

CNC Machine Control Manufacturer
Fanuc
Control Model
16/18/21, 16i/18i/21i, 160i/180i/210i, 0/00/0-mate, 0i
90 - REFERENCE RETURN INCOMPLETE

Alarm Description

The reference position return cannot be performed normally because the reference position return start point is too close to the reference position or the speed is too slow. Separate the start point far enough from the reference position, or specify a sufficiently fast speed for reference position return. Check the program contents.

Additional Suggestions & Alarm Clarification

None currently

Help Others
Post troubleshooting recommendations for (Fanuc alarm: 90 - REFERENCE RETURN INCOMPLETE) error message below.

Fanuc alarm: 89 - LAN FILE TRANS ERROR (CHANNEL-2)

CNC Machine Control Manufacturer
Fanuc
Control Model
16/18/21, 16i/18i/21i, 160i/180i/210i, ,
89 - LAN FILE TRANS ERROR (CHANNEL-2)

Alarm Description

File data transfer via OSI-ETHERNET has been stopped due to a transfer error.

Additional Suggestions & Alarm Clarification

None currently

Help Others
Post troubleshooting recommendations for (Fanuc alarm: 89 - LAN FILE TRANS ERROR (CHANNEL-2)) error message below.

Fanuc alarm: 88 - LAN FILE TRANS ERROR (CHANNEL-1)

CNC Machine Control Manufacturer
Fanuc
Control Model
16/18/21, 16i/18i/21i, 160i/180i/210i, ,
88 - LAN FILE TRANS ERROR (CHANNEL-1)

Alarm Description

File data transfer via OSI-ETHERNET has been stopped due to a transfer error.

Additional Suggestions & Alarm Clarification

None currently

Help Others
Post troubleshooting recommendations for (Fanuc alarm: 88 - LAN FILE TRANS ERROR (CHANNEL-1)) error message below.

Fanuc alarm: 87 - BUFFER OVERFLOW

CNC Machine Control Manufacturer
Fanuc
Control Model
16/18/21, 16i/18i/21i, 160i/180i/210i, 0/00/0-mate, 0i
87 - BUFFER OVERFLOW

Alarm Description

When entering data in the memory by using Reader / Puncher interface, though the read terminate command is specified, input is not interrupted after 10 characters read. I/O unit or P.C.B. is defective.

Additional Suggestions & Alarm Clarification

None currently

Help Others
Post troubleshooting recommendations for (Fanuc alarm: 87 - BUFFER OVERFLOW) error message below.

Fanuc alarm: 86 - DR SIGNAL OFF

CNC Machine Control Manufacturer
Fanuc
Control Model
16/18/21, 16i/18i/21i, 160i/180i/210i, 0/00/0-mate, 0i
86 - DR SIGNAL OFF

Alarm Description

When entering data in the memory by using Reader / Puncher interface, the ready signal (DR) of reader / puncher was turned off. Power supply of I/O unit is off or cable is not connected or a P.C.B. is defective.

Additional Suggestions & Alarm Clarification

None currently

Help Others
Post troubleshooting recommendations for (Fanuc alarm: 86 - DR SIGNAL OFF) error message below.

Fanuc alarm: 85 - COMMUNICATION ERROR

CNC Machine Control Manufacturer
Fanuc
Control Model
16/18/21, 16i/18i/21i, 160i/180i/210i, 0/00/0-mate, 0i
85 - COMMUNICATION ERROR

Alarm Description

When entering data in the memory by using Reader / Puncher interface, an overrun, parity or framing error was generated. The number of bits of input data or setting of baud rate or specification No. of I/O unit is in correct.

Additional Suggestions & Alarm Clarification

None currently

Help Others
Post troubleshooting recommendations for (Fanuc alarm: 85 - COMMUNICATION ERROR) error message below.

Fanuc alarm: 83 - ILLEGAL AXIS COMMAND IN G37

CNC Machine Control Manufacturer
Fanuc
Control Model
16/18/21, 16i/18i/21i, 160i/180i/210i, 0/00/0-mate, 0i
83 - ILLEGAL AXIS COMMAND IN G37

Alarm Description

In automatic tool length measurement or automatic tool compensation (G36, G37), an invalid axis was specified or the command is incremental. Modify the program.

Additional Suggestions & Alarm Clarification

None currently

Help Others
Post troubleshooting recommendations for (Fanuc alarm: 83 - ILLEGAL AXIS COMMAND IN G37) error message below.