16/18/21

Fanuc alarm: 749 - S-SPINDLE LSI ERROR

CNC Machine Control Manufacturer
Fanuc
Control Model
16/18/21, 16i/18i/21i, 160i/180i/210i, , 0i
749 - S-SPINDLE LSI ERROR

Alarm Description

It is serial communication error while system is executing after power supply on. Following reasons can be considered. 1) Optical cable connection is fault or cable is not connected or cable is cut. 2) MAIN CPU board or option 2 board is fault. 3) Spindle amp. printed board is fault. If this alarm occurs when CNC power supply is turned on or when this alarm can not be cleared even if CNC is reset, turn off the power supply also turn off the power supply in spindle side.

Additional Suggestions & Alarm Clarification

None currently

Help Others
Post troubleshooting recommendations for (Fanuc alarm: 749 - S-SPINDLE LSI ERROR) error message below.

Fanuc alarm: 742 - RIGID TAP ALARM: LSI OVERFLOW

CNC Machine Control Manufacturer
Fanuc
Control Model
16/18/21, 16i/18i/21i, 160i/180i/210i, , 0i
742 - RIGID TAP ALARM: LSI OVERFLOW

Alarm Description

An LSI overflow has occurred for the spindle during rigid tapping.

Additional Suggestions & Alarm Clarification

None currently

Help Others
Post troubleshooting recommendations for (Fanuc alarm: 742 - RIGID TAP ALARM: LSI OVERFLOW) error message below.

Fanuc alarm: 741 - RIGID TAP ALARM: EXCESS ERROR

CNC Machine Control Manufacturer
Fanuc
Control Model
16/18/21, 16i/18i/21i, 160i/180i/210i, , 0i
741 - RIGID TAP ALARM: EXCESS ERROR

Alarm Description

The positional deviation of the moving spindle has exceeded the set value during rigid tapping.

Additional Suggestions & Alarm Clarification

None currently

Help Others
Post troubleshooting recommendations for (Fanuc alarm: 741 - RIGID TAP ALARM: EXCESS ERROR) error message below.

Fanuc alarm: 740 - RIGID TAP ALARM: EXCESS ERROR

CNC Machine Control Manufacturer
Fanuc
Control Model
16/18/21, 16i/18i/21i, 160i/180i/210i, , 0i
740 - RIGID TAP ALARM: EXCESS ERROR

Alarm Description

The positional deviation of the stopped spindle has exceeded the set value during rigid tapping.

Additional Suggestions & Alarm Clarification

None currently

Help Others
Post troubleshooting recommendations for (Fanuc alarm: 740 - RIGID TAP ALARM: EXCESS ERROR) error message below.

Fanuc alarm: 704 - OVERHEAT: SPINDLE

CNC Machine Control Manufacturer
Fanuc
Control Model
16/18/21, 16i/18i/21i, 160i/180i/210i, 0/00/0-mate, 0i
704 - OVERHEAT: SPINDLE

Alarm Description

Spindle overheat in the spindle fluctuation detection (1) If the cutting load is heavy, relieve the cutting condition. (2) Check whether the cutting tool is share. (3) Another possible cause is a faulty spindle amp.

Additional Suggestions & Alarm Clarification

None currently

Help Others
Post troubleshooting recommendations for (Fanuc alarm: 704 - OVERHEAT: SPINDLE) error message below.

Fanuc alarm: 701 - OVERHEAT: FAN MOTOR

CNC Machine Control Manufacturer
Fanuc
Control Model
16/18/21, 16i/18i/21i, 160i/180i/210i, , 0i
701 - OVERHEAT: FAN MOTOR

Alarm Description

The fan motor on the top of the cabinet for the control unit is overheated. Check the operation of the fan motor and replace the motor if necessary.

Additional Suggestions & Alarm Clarification

None currently

Help Others
Post troubleshooting recommendations for (Fanuc alarm: 701 - OVERHEAT: FAN MOTOR) error message below.

Fanuc alarm: 700 - OVERHEAT: CONTROL UNIT

CNC Machine Control Manufacturer
Fanuc
Control Model
16/18/21, 16i/18i/21i, 160i/180i/210i, 0/00/0-mate, 0i
700 - OVERHEAT: CONTROL UNIT

Alarm Description

Control unit overheat Check that the fan motor operates normally, and clean the air filter.

Additional Suggestions & Alarm Clarification

None currently

Help Others
Post troubleshooting recommendations for (Fanuc alarm: 700 - OVERHEAT: CONTROL UNIT) error message below.

Fanuc alarm: 511 - OVER TRAVEL: -n

CNC Machine Control Manufacturer
Fanuc
Control Model
16/18/21, 16i/18i/21i, 160i/180i/210i, ,
511 - OVER TRAVEL: -n

Alarm Description

Alarm for stroke check prior to movement. The end point specified in a block falls within the forbidden area defined with the stroke check in the negative direction along the N axis. Correct the program.

Additional Suggestions & Alarm Clarification

None currently

Help Others
Post troubleshooting recommendations for (Fanuc alarm: 511 - OVER TRAVEL: -n) error message below.

Fanuc alarm: 510 - OVER TRAVEL: +n

CNC Machine Control Manufacturer
Fanuc
Control Model
16/18/21, 16i/18i/21i, 160i/180i/210i, ,
510 - OVER TRAVEL: +n

Alarm Description

Alarm for stroke check prior to movement. The end point specified in a block falls within the forbidden area defined with the stroke check in the positive direction along the N axis. Correct the program.

Additional Suggestions & Alarm Clarification

None currently

Help Others
Post troubleshooting recommendations for (Fanuc alarm: 510 - OVER TRAVEL: +n) error message below.

Fanuc alarm: 509 - INTERFERENCE: -n (T series (two-path control))

CNC Machine Control Manufacturer
Fanuc
Control Model
16/18/21, 16i/18i/21i, 160i/180i/210i, ,
509 - INTERFERENCE: -n (T series (two-path control))

Alarm Description

A tool moving in the negative direction along the n axis has fouled another tool post.

Additional Suggestions & Alarm Clarification

None currently

Help Others
Post troubleshooting recommendations for (Fanuc alarm: 509 - INTERFERENCE: -n (T series (two-path control))) error message below.