16/18/21

Fanuc alarm: 976 - L-BUS ERROR

CNC Machine Control Manufacturer
Fanuc
Control Model
16/18/21, 16i/18i/21i, 160i/180i/210i, ,
976 - L-BUS ERROR

Alarm Description

A bus error occurred on the local bus. The motherboard may be faulty.

Additional Suggestions & Alarm Clarification

None currently

Help Others
Post troubleshooting recommendations for (Fanuc alarm: 976 - L-BUS ERROR) error message below.

Fanuc alarm: 975 - BUS ERROR

CNC Machine Control Manufacturer
Fanuc
Control Model
16/18/21, 16i/18i/21i, 160i/180i/210i, ,
975 - BUS ERROR

Alarm Description

A bus error occurred on the motherboard. The motherboard may be faulty.

Additional Suggestions & Alarm Clarification

None currently

Help Others
Post troubleshooting recommendations for (Fanuc alarm: 975 - BUS ERROR) error message below.

Fanuc alarm: 974 - F-BUS ERROR

CNC Machine Control Manufacturer
Fanuc
Control Model
16/18/21, 16i/18i/21i, 160i/180i/210i, , 0i
974 - F-BUS ERROR

Alarm Description

A bus error occurred on the FANUC bus. The motherboard or option board may be faulty.

Additional Suggestions & Alarm Clarification

None currently

Help Others
Post troubleshooting recommendations for (Fanuc alarm: 974 - F-BUS ERROR) error message below.

Fanuc alarm: 972 - NMI OCCURRED IN OTHER MODULE

CNC Machine Control Manufacturer
Fanuc
Control Model
16/18/21, 16i/18i/21i, 160i/180i/210i, ,
972 - NMI OCCURRED IN OTHER MODULE

Alarm Description

An NMI occurred on a board other than the motherboard. The option board may be faulty.

Additional Suggestions & Alarm Clarification

None currently

Help Others
Post troubleshooting recommendations for (Fanuc alarm: 972 - NMI OCCURRED IN OTHER MODULE) error message below.

Fanuc alarm: 971 - NMI OCCURRED IN SLC

CNC Machine Control Manufacturer
Fanuc
Control Model
16/18/21, 16i/18i/21i, 160i/180i/210i, , 0i
971 - NMI OCCURRED IN SLC

Alarm Description

An alarm condition occurred in the interface with an I/O unit. For PMC-
RA1, PMC-RA2, and PMC-RB, check that the PMC control module on
the main CPU board is conneted to the I/O unit securely. For PMC-RC,
check that the PMC control module on the option 3 board is connected
to the I/O unit is supplied with power and that the interface module is intact.

Additional Suggestions & Alarm Clarification

None currently

Help Others
Post troubleshooting recommendations for (Fanuc alarm: 971 - NMI OCCURRED IN SLC) error message below.

Fanuc alarm: 970 - NMI OCCURRED IN PMP

CNC Machine Control Manufacturer
Fanuc
Control Model
16/18/21, 16i/18i/21i, 160i/180i/210i, ,
970 - NMI OCCURRED IN PMP

Alarm Description

RAM parity error or NMI occurred in the PMC-RB module.
The main CPU board is faulty.

Additional Suggestions & Alarm Clarification

None currently

Help Others
Post troubleshooting recommendations for (Fanuc alarm: 970 - NMI OCCURRED IN PMP) error message below.

Fanuc alarm: 951 - PMC WATCH DOG ALARM

CNC Machine Control Manufacturer
Fanuc
Control Model
16/18/21, 16i/18i/21i, 160i/180i/210i, ,
951 - PMC WATCH DOG ALARM

Alarm Description

An error occurred in the PMC. (Watchdog alarm) The motherboard may be faulty.

Additional Suggestions & Alarm Clarification

Check all voltages for power supplies and incomming power

Help Others
Post troubleshooting recommendations for (Fanuc alarm: 951 - PMC WATCH DOG ALARM) error message below.

Fanuc alarm: 950 - PMC SYSTEM ALARM

CNC Machine Control Manufacturer
Fanuc
Control Model
16/18/21, 16i/18i/21i, 160i/180i/210i, , 0i
950 - PMC SYSTEM ALARM

Alarm Description

An error occurred in the PMC. The PMC control circuit on the motherboard may be faulty.

Additional Suggestions & Alarm Clarification

Check all voltages for power supplies and incomming power

Help Others
Post troubleshooting recommendations for (Fanuc alarm: 950 - PMC SYSTEM ALARM) error message below.

Fanuc alarm: 945 - SERIAL SPINDLE COMMUNICATIONERROR

CNC Machine Control Manufacturer
Fanuc
Control Model
16/18/21, 16i/18i/21i, 160i/180i/210i, 0/00/0-mate,
945 - SERIAL SPINDLE COMMUNICATIONERROR

Alarm Description

Communications error occured in the serial spindle.The optical fiber may be disconnected. The hardware configuration is incorrect for the serial spindle, or a communication alarm occurred. Check the hardware configuration of
the spindle. Also ensure that the hardware for the serial spindle is
connected securely.

Additional Suggestions & Alarm Clarification

None currently

Help Others
Post troubleshooting recommendations for (Fanuc alarm: 945 - SERIAL SPINDLE COMMUNICATIONERROR) error message below.

Theme by Danetsoft and Danang Probo Sayekti inspired by Maksimer