0i

Fanuc alarm: 740 - RIGID TAP ALARM: EXCESS ERROR

CNC Machine Control Manufacturer
Fanuc
Control Model
16/18/21, 16i/18i/21i, 160i/180i/210i, , 0i
740 - RIGID TAP ALARM: EXCESS ERROR

Alarm Description

The positional deviation of the stopped spindle has exceeded the set value during rigid tapping.

Additional Suggestions & Alarm Clarification

None currently

Help Others
Post troubleshooting recommendations for (Fanuc alarm: 740 - RIGID TAP ALARM: EXCESS ERROR) error message below.

Fanuc alarm: 704 - OVERHEAT: SPINDLE

CNC Machine Control Manufacturer
Fanuc
Control Model
16/18/21, 16i/18i/21i, 160i/180i/210i, 0/00/0-mate, 0i
704 - OVERHEAT: SPINDLE

Alarm Description

Spindle overheat in the spindle fluctuation detection (1) If the cutting load is heavy, relieve the cutting condition. (2) Check whether the cutting tool is share. (3) Another possible cause is a faulty spindle amp.

Additional Suggestions & Alarm Clarification

None currently

Help Others
Post troubleshooting recommendations for (Fanuc alarm: 704 - OVERHEAT: SPINDLE) error message below.

Fanuc alarm: 701 - OVERHEAT: FAN MOTOR

CNC Machine Control Manufacturer
Fanuc
Control Model
16/18/21, 16i/18i/21i, 160i/180i/210i, , 0i
701 - OVERHEAT: FAN MOTOR

Alarm Description

The fan motor on the top of the cabinet for the control unit is overheated. Check the operation of the fan motor and replace the motor if necessary.

Additional Suggestions & Alarm Clarification

None currently

Help Others
Post troubleshooting recommendations for (Fanuc alarm: 701 - OVERHEAT: FAN MOTOR) error message below.

Fanuc alarm: 700 - OVERHEAT: CONTROL UNIT

CNC Machine Control Manufacturer
Fanuc
Control Model
16/18/21, 16i/18i/21i, 160i/180i/210i, 0/00/0-mate, 0i
700 - OVERHEAT: CONTROL UNIT

Alarm Description

Control unit overheat Check that the fan motor operates normally, and clean the air filter.

Additional Suggestions & Alarm Clarification

None currently

Help Others
Post troubleshooting recommendations for (Fanuc alarm: 700 - OVERHEAT: CONTROL UNIT) error message below.

Fanuc alarm: 507 - OVER TRAVEL : -n

CNC Machine Control Manufacturer
Fanuc
Control Model
16/18/21, 16i/18i/21i, 160i/180i/210i, , 0i
507 - OVER TRAVEL : -n

Alarm Description

Exceeded the n-th axis (axis 1-8) -side hardware OT.

Additional Suggestions & Alarm Clarification

Soft overtravel or hard overtravel means the axis is out of the stroke limit set up in the parameters. Move axis to with in its stroke limit.

Help Others
Post troubleshooting recommendations for (Fanuc alarm: 507 - OVER TRAVEL : -n) error message below.

Fanuc alarm: 506 - OVER TRAVEL : +n

CNC Machine Control Manufacturer
Fanuc
Control Model
16/18/21, 16i/18i/21i, 160i/180i/210i, , 0i
506 - OVER TRAVEL : +n

Alarm Description

Exceeded the n-th axis (axis 1-8) + side hardware OT.

Additional Suggestions & Alarm Clarification

Soft overtravel or hard overtravel means the axis is out of the stroke limit set up in the parameters. Move axis to with in its stroke limit.

Help Others
Post troubleshooting recommendations for (Fanuc alarm: 506 - OVER TRAVEL : +n) error message below.

Fanuc alarm: 505 - OVER TRAVEL : -n

CNC Machine Control Manufacturer
Fanuc
Control Model
16/18/21, 16i/18i/21i, 160i/180i/210i, , 0i
505 - OVER TRAVEL : -n

Alarm Description

Exceeded the n-th axis (axis 1-8) -side stored stroke check III. (Parameter No.1325 )

Additional Suggestions & Alarm Clarification

Soft overtravel or hard overtravel means the axis is out of the stroke limit set up in the parameters. Move axis to with in its stroke limit.

Help Others
Post troubleshooting recommendations for (Fanuc alarm: 505 - OVER TRAVEL : -n) error message below.

Fanuc alarm: 504 - OVER TRAVEL : +n

CNC Machine Control Manufacturer
Fanuc
Control Model
16/18/21, 16i/18i/21i, 160i/180i/210i, , 0i
504 - OVER TRAVEL : +n

Alarm Description

Exceeded the n-th axis (axis 1-8) + side stored stroke check III. (Parameter No.1324 )

Additional Suggestions & Alarm Clarification

Soft overtravel or hard overtravel means the axis is out of the stroke limit set up in the parameters. Move axis to with in its stroke limit.

Help Others
Post troubleshooting recommendations for (Fanuc alarm: 504 - OVER TRAVEL : +n) error message below.

Fanuc alarm: 503 - OVER TRAVEL : -n

CNC Machine Control Manufacturer
Fanuc
Control Model
16/18/21, 16i/18i/21i, 160i/180i/210i, , 0i
503 - OVER TRAVEL : -n

Alarm Description

Exceeded the n-th axis (axis 1-8) -side stored stroke check II. (Parameter No.1323)

Additional Suggestions & Alarm Clarification

Soft overtravel or hard overtravel means the axis is out of the stroke limit set up in the parameters. Move axis to with in its stroke limit.

Help Others
Post troubleshooting recommendations for (Fanuc alarm: 503 - OVER TRAVEL : -n) error message below.

Fanuc alarm: 502 - OVER TRAVEL : +n

CNC Machine Control Manufacturer
Fanuc
Control Model
16/18/21, 16i/18i/21i, 160i/180i/210i, , 0i
502 - OVER TRAVEL : +n

Alarm Description

Exceeded the n-th axis (axis 1-8) + side stored stroke check II. (Parameter No.1322 )

Additional Suggestions & Alarm Clarification

Soft overtravel or hard overtravel means the axis is out of the stroke limit set up in the parameters. Move axis to with in its stroke limit.

Help Others
Post troubleshooting recommendations for (Fanuc alarm: 502 - OVER TRAVEL : +n) error message below.

Theme by Danetsoft and Danang Probo Sayekti inspired by Maksimer