Yasnac alarm: 323 - ACGC2 SYNC ERROR
Synchronous error of ACGC 120 CPU and NC Side CPU> (Set #6014D5 to 0 for release)
- Read more about Yasnac alarm: 323 - ACGC2 SYNC ERROR
- Log in to post comments
Yasnac, Yaskawa CNC controls models
Synchronous error of ACGC 120 CPU and NC Side CPU> (Set #6014D5 to 0 for release)
THE UNUSED AREA OF THE CMOS IS USED. (THE CMOS MAY BE DESTROYED.) (SET "1" IN #6066 D2 TO RESET THE ERROR.)
NC UNREADY P SET NOT READY
The power on circuit for the main control is not ready. There may be another button that needs to be pushed to ready up the control or another machine condition that must be satisfied before NC Ready comes on.
5TH AXIS SERVO NOT READY
Servo Drives are off. Condition exists that is not allowing a power on. Check drives for faults or Fault LEDS.
4TH AXIS SERVO NOT READY
Servo Drives are off. Condition exists that is not allowing a power on. Check drives for faults or Fault LEDS.
Z-AXIS SERVO NOT READY
Servo Drives are off. Condition exists that is not allowing a power on. Check drives for faults or Fault LEDS.
Y-AXIS SERVO NOT READY
Servo Drives are off. Condition exists that is not allowing a power on. Check drives for faults or Fault LEDS.
X-AXIS SERVO NOT READY
Servo Drives are off. Condition exists that is not allowing a power on. Check drives for faults or Fault LEDS.
SERVO POWER NOT SUPPLIED
Servo Drives are off. Condition exists that is not allowing a power on. Check drives for faults or Fault LEDS.
REFERENCE POINT RETURN COMPLETED WITH REFERENCE POINT LS OFF.