Yaskawa

Yasnac, Yaskawa CNC controls models

Yasnac alarm: 392 - TG ERROR (Y) or (Z-LX)

CNC Alarm Error Message
392 - TG ERROR (Y) or (Z-LX)
Control Manufacturer
Yaskawa
Control Model
MX1, MX2, LX1, LX2,

Yaskawa/Yasnac CNC Machine Alarm Description

TAC GENERATOR ERROR Y or Z

Additional Suggestions & Alarm Clarification

Possible encoder, cable, or drive is bad. Swap encoder or drive to try to determine which is the problem. Also some alarms come up on drive on power up with only the main breaker. If it does it

<p></p>
Help Others
Post CNC machine troubleshooting recommendations for (Yasnac alarm: 392 - TG ERROR (Y) or (Z-LX)) error message below.

Yasnac alarm: 391 - TG ERROR (X)

CNC Alarm Error Message
391 - TG ERROR (X)
Control Manufacturer
Yaskawa
Control Model
MX1, MX2

Yaskawa/Yasnac CNC Machine Alarm Description

TAC GENERATOR ERROR X

Additional Suggestions & Alarm Clarification

Possible encoder, cable, or drive is bad. Swap encoder or drive to try to determine which is the problem. Also some alarms come up on drive on power up with only the main breaker. If it does it

<p></p>
Help Others
Post CNC machine troubleshooting recommendations for (Yasnac alarm: 391 - TG ERROR (X)) error message below.

Yasnac alarm: 390 - SERVO ALARM (SERVOPACK- S) SR20

CNC Alarm Error Message
390 - SERVO ALARM (SERVOPACK- S) SR20
Control Manufacturer
Yaskawa
Control Model
J50, MX3, LX3

Yaskawa/Yasnac CNC Machine Alarm Description

SERVOPACK ALARM SPINDLE PG DISCONNECTION OF 4/5 AXIS SR FAILURE

<p></p>
Help Others
Post CNC machine troubleshooting recommendations for (Yasnac alarm: 390 - SERVO ALARM (SERVOPACK- S) SR20) error message below.