Yasnac-I80 CNC alarm: #3172
(1) ENCODER UNMATCH (Y) (2) Improper parameter setting of encoder type (Y-axis)
- Read more about Yasnac-I80 CNC alarm: #3172
- Log in to post comments
Yasnac, Yaskawa CNC controls models
(1) ENCODER UNMATCH (Y) (2) Improper parameter setting of encoder type (Y-axis)
(1) ENCODER UNMATCH (X) (2) Improper parameter of encoder type (X-axis)
(1) ABSO ERROR (5) (2) Malfunction detection of absolute value encoder (5th-axis)
Most likely bad encoder or bad cable. Try swapping encoders if possible with another axis if they are the same. Ohm out the cable or purchase new encoder or cable.
(1) ABSO ERROR (4) (2) Malfunction detection of absolute value encoder (4th-axis)
Most likely bad encoder or bad cable. Try swapping encoders if possible with another axis if they are the same. Ohm out the cable or purchase new encoder or cable.
(1) ABSO ERROR (Z) (2) Malfunction detection of absolute value encoder (Z-axis)
Most likely bad encoder or bad cable. Try swapping encoders if possible with another axis if they are the same. Ohm out the cable or purchase new encoder or cable.
(1) ABSO ERROR (Y) (2) Malfunction detection of absolute value encoder (Y-axis)
Most likely bad encoder or bad cable. Try swapping encoders if possible with another axis if they are the same. Ohm out the cable or purchase new encoder or cable.
(1) ABSO ERROR (X) (2) Malfunction detection of absolute value encoder (X-axis)
Most likely bad encoder or bad cable. Try swapping encoders if possible with another axis if they are the same. Ohm out the cable or purchase new encoder or cable.
(1) OVERRUN PREVENTION (5) (2) Servo axis overrun detection (5th-axis)
(1) OVERRUN PREVENTION (4) (2) Servo axis overrun detection (4th-axis)
(1) OVERRUN PREVENTION (Z) (2) Servo axis overrun detection (Z-axis)
Theme by Danetsoft and Danang Probo Sayekti inspired by Maksimer