Yasnac-I80 CNC alarm: #2172
(1) AXIS DETACHED STATUS UNMATCH (Y) (2) Detachment input went off when Y-axis was disconnected (Y-axis)
- Read more about Yasnac-I80 CNC alarm: #2172
- Log in to post comments
Yasnac I80 CNC alarms database listing and reference.
(1) AXIS DETACHED STATUS UNMATCH (Y) (2) Detachment input went off when Y-axis was disconnected (Y-axis)
(1) AXIS DETACHED STATUS UNMATCH (X) (2) Detachment input went off when X-axis was disconnected. (X-axis)
(1) DETACHED AX 1 S SERVO ON (5) (2) Detachment input went on when servo was on (5th-axis)
(1) DETACHED AXIS SERVO ON (4) (2) Detachment input went on when servo was on (4th-axis)
Check your cables are connected and wires are connected to pins in plugs.
(1) DETACHED AXIS SERVO ON (Z) (2) Detachment input went on when servo was on (Z-axis)
Check your cables are connected and wires are connected to pins in plugs.
(1) DETACHED AXIS SERVO ON (V) (2) Detachment input went on when servo was on (Y-axis)
Check your cables are connected and wires are connected to pins in plugs.
(1) DETACHED AXIS SERVO ON (X) (2) Detachment input went on when servo on (X-axis)
Check your cables are connected and wires are connected to pins in plugs.
(1) ABSO POS CHECK ERROR (5) (2) The difference between the positions when the power supply of the absolute position detecting function is turned on and when the power supply is turned off at the previous time is large.
Rezero machine, axis was moved with power off to the control or power was lost while during the machining operation, or an axis might have been pushed or ballscrew turned with the power off to the control.
(1) ABSO POS CHECK ERROR (4) (2) The difference between the positions when the power supply of the absolute position detecting function is turned on and when the power supply is turned off at the previous time is large.
Rezero machine, axis was moved with power off to the control or power was lost while during the machining operation, or an axis might have been pushed or ballscrew turned with the power off to the control.
(1) ABSO POS CHECK ERROR (Z) (2) The difference between the positions when the power supply of the absolute position detecting function is turned on and when the power supply is turned off at the previous time is large.
Rezero machine, axis was moved with power off to the control or power was lost while during the machining operation, or an axis might have been pushed or ballscrew turned with the power off to the control.