I80

Yasnac I80 CNC alarms database listing and reference.

Yasnac-I80 CNC alarm: #3172

CNC Alarm Error Message
#3172
Control Manufacturer
Yaskawa
Control Model
I80

Yaskawa/Yasnac CNC Machine Alarm Description

(1) ENCODER UNMATCH (Y) (2) Improper parameter setting of encoder type (Y-axis)

<p></p>
Help Others
Post your suggestions for troubleshooting and repairing CNC alarm (Yasnac-I80 CNC alarm: #3172) error message below.

Yasnac-I80 CNC alarm: #3171

CNC Alarm Error Message
#3171
Control Manufacturer
Yaskawa
Control Model
I80

Yaskawa/Yasnac CNC Machine Alarm Description

(1) ENCODER UNMATCH (X) (2) Improper parameter of encoder type (X-axis)

<p></p>
Help Others
Post your suggestions for troubleshooting and repairing CNC alarm (Yasnac-I80 CNC alarm: #3171) error message below.

Yasnac-I80 CNC alarm: #3165

CNC Alarm Error Message
#3165
Control Manufacturer
Yaskawa
Control Model
I80

Yaskawa/Yasnac CNC Machine Alarm Description

(1) ABSO ERROR (5) (2) Malfunction detection of absolute value encoder (5th-axis)

Additional Suggestions & Alarm Clarification

Most likely bad encoder or bad cable. Try swapping encoders if possible with another axis if they are the same. Ohm out the cable or purchase new encoder or cable.

<p></p>
Help Others
Post your suggestions for troubleshooting and repairing CNC alarm (Yasnac-I80 CNC alarm: #3165) error message below.

Yasnac-I80 CNC alarm: #3164

CNC Alarm Error Message
#3164
Control Manufacturer
Yaskawa
Control Model
I80

Yaskawa/Yasnac CNC Machine Alarm Description

(1) ABSO ERROR (4) (2) Malfunction detection of absolute value encoder (4th-axis)

Additional Suggestions & Alarm Clarification

Most likely bad encoder or bad cable. Try swapping encoders if possible with another axis if they are the same. Ohm out the cable or purchase new encoder or cable.

<p></p>
Help Others
Post your suggestions for troubleshooting and repairing CNC alarm (Yasnac-I80 CNC alarm: #3164) error message below.

Yasnac-I80 CNC alarm: #3163

CNC Alarm Error Message
#3163
Control Manufacturer
Yaskawa
Control Model
I80

Yaskawa/Yasnac CNC Machine Alarm Description

(1) ABSO ERROR (Z) (2) Malfunction detection of absolute value encoder (Z-axis)

Additional Suggestions & Alarm Clarification

Most likely bad encoder or bad cable. Try swapping encoders if possible with another axis if they are the same. Ohm out the cable or purchase new encoder or cable.

<p></p>
Help Others
Post your suggestions for troubleshooting and repairing CNC alarm (Yasnac-I80 CNC alarm: #3163) error message below.

Yasnac-I80 CNC alarm: #3162

CNC Alarm Error Message
#3162
Control Manufacturer
Yaskawa
Control Model
I80

Yaskawa/Yasnac CNC Machine Alarm Description

(1) ABSO ERROR (Y) (2) Malfunction detection of absolute value encoder (Y-axis)

Additional Suggestions & Alarm Clarification

Most likely bad encoder or bad cable. Try swapping encoders if possible with another axis if they are the same. Ohm out the cable or purchase new encoder or cable.

<p></p>
Help Others
Post your suggestions for troubleshooting and repairing CNC alarm (Yasnac-I80 CNC alarm: #3162) error message below.

Yasnac-I80 CNC alarm: #3161

CNC Alarm Error Message
#3161
Control Manufacturer
Yaskawa
Control Model
I80

Yaskawa/Yasnac CNC Machine Alarm Description

(1) ABSO ERROR (X) (2) Malfunction detection of absolute value encoder (X-axis)

Additional Suggestions & Alarm Clarification

Most likely bad encoder or bad cable. Try swapping encoders if possible with another axis if they are the same. Ohm out the cable or purchase new encoder or cable.

<p></p>
Help Others
Post your suggestions for troubleshooting and repairing CNC alarm (Yasnac-I80 CNC alarm: #3161) error message below.

Yasnac-I80 CNC alarm: #3145

CNC Alarm Error Message
#3145
Control Manufacturer
Yaskawa
Control Model
I80

Yaskawa/Yasnac CNC Machine Alarm Description

(1) OVERRUN PREVENTION (5) (2) Servo axis overrun detection (5th-axis)

<p></p>
Help Others
Post your suggestions for troubleshooting and repairing CNC alarm (Yasnac-I80 CNC alarm: #3145) error message below.

Yasnac-I80 CNC alarm: #3144

CNC Alarm Error Message
#3144
Control Manufacturer
Yaskawa
Control Model
I80

Yaskawa/Yasnac CNC Machine Alarm Description

(1) OVERRUN PREVENTION (4) (2) Servo axis overrun detection (4th-axis)

<p></p>
Help Others
Post your suggestions for troubleshooting and repairing CNC alarm (Yasnac-I80 CNC alarm: #3144) error message below.

Yasnac-I80 CNC alarm: #3143

CNC Alarm Error Message
#3143
Control Manufacturer
Yaskawa
Control Model
I80

Yaskawa/Yasnac CNC Machine Alarm Description

(1) OVERRUN PREVENTION (Z) (2) Servo axis overrun detection (Z-axis)

<p></p>
Help Others
Post your suggestions for troubleshooting and repairing CNC alarm (Yasnac-I80 CNC alarm: #3143) error message below.

Theme by Danetsoft and Danang Probo Sayekti inspired by Maksimer