Yasnac alarm: 120 - PRTN ERROR (NOT FOUND)
SEQUENCE NO. NOT FOUND INPART PROGRAM.
- Read more about Yasnac alarm: 120 - PRTN ERROR (NOT FOUND)
- Log in to post comments
Yasnac MX2 CNC error codes and alarms
SEQUENCE NO. NOT FOUND INPART PROGRAM.
CONDITION O ? n ? 9999 NOT ESTABLISHED OR NO SEQUENCE NO. IN GOTO n.
CONDITION 1 ? m ? 3 NOT ESTABLISHED IN DOm.
NO. OF LEFT BRACKETS AND RIGHT BRACKETS NOT THE SAME. FORMAT ERROR
NO. OF Dos AND ENDs NOT THE SAME.
LEVEL FOR CALLING MACRO EXCEEDING FOUR LEVELS.
MOVE COMMAND IN M99 FINISHING COMMAND OF MACRO CALLED BY G66.
MULTIPLE LAYERS OF PARENTHESES EXCEEDING THE UPPER LIMIT (5).
COMMANDED PROHIBITED VARIABLE AS SUBSTITUTION IN LEFT-HAND SIDE OF THE EQUATION.