Fanuc alarm: SV009 - EXCESS ERROR (MOVING)

CNC Machine Control Manufacturer
Fanuc
Control Model
10/11/12
SV009 - EXCESS ERROR (MOVING)
Alarm Description

Position deviation amount during moving is larger than the value preset by parameter No. 1828.

Additional Suggestions & Alarm Clarification

The axis has shifted for some reason or did not get to where it was being commanded. Could be excessive load in axis, axis lube problems or something along them lines.

Help Others
Any additional suggestions or recommendations on the Fanuc alarm: SV009 - EXCESS ERROR (MOVING) message please post comments below.